Unique Home Designs IWG0400BLACK6B Instruction Manual

Browse online or download Instruction Manual for Unknown Unique Home Designs IWG0400BLACK6B. Unique Home Designs IWG0400BLACK6B Instructions / Assembly User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Fig. C
Window stop L-bracket installation
Vertical channel
1/2" off sill
Secure window stop
L-brackets with
one-way screws
4
"
maximum
clearance below
uppermost bottom
horizontal bar
4
"
maximum
clearance above
lowermost top
horizontal bar
Front View
WINDOW
FRAME
Z
Vertical channel
1/2" off sill
Mounting to the surface of the window frame
Fig. B
Y
Y
Front View
WINDOW
FRAME
Top View
X
l
Front View
Vertical channel
1/2" off sill
Hinged channel Vertical end-channels
Mounting within the window frame
WINDOW
FRAME
Fig. A
Top View
X
Y
Locking channel
INSTALLATION INSTRUCTIONS
Pivoting Installation
To meet proposed ASTM standards, follow specied instructions.
1. Expand and place window guard in desired position against window
frame allowing no more than 1/2" clearance between the sill and the
bottom of the vertical channels.
Note: To maintain safety requirements, the clearance between the
sill and the uppermost section of the bottom horizontal bars must
be no more than 4" (Fig. C).
2. Using the vertical end-channels as a guide, mark locations of holes,
through hinge and locking channels. Remove guard and pre-drill
holes using a 3/32" drill bit.
3. Reposition the window guard in place and secure, through
the hinged and locking channels only, using the #10 x 1-1/2"
one-way screws provided. Adjust as necessary making sure that the
window guard swings and engages the locking channel freely.
Note: The use of any locking or latching hardware must allow for
quick exit in the event of an emergency. An optional Quick
Release Kit locking system is available, for interior installation
only (sold separately).
Non-Pivoting Installation
1. Expand and place window guard in desired position against window
frame allowing no more than 1/2" clearance between the sill and the
bottom of the vertical channels.
Note: To maintain safety requirements, the clearance between the
sill and the uppermost bottom horizontal bar conguration must be
no more than 4" (Fig. C).
2. Using the vertical end-channels as a guide, mark locations of holes,
through hinge and locking channels. Remove guard and pre-drill
holes using a 3/32" drill bit.
3. Reposition the window guard in place and secure, through vertical
end-channels and proceeding through the hinged and locking
channels, using the #10 x 1-1/2" one-way screws provided.
Window Stop Installation
The L-bracket is designed to limit the bottom window sash from
opening more than 4" above the lowermost section of the top
horizontal bars. Raise or lower the bottom window sash to the
appropriate level. Position one L-bracket on each side of the window
track, above the window sash, and secure in place using two of the
provided #10 x 1-1/2" one-way screws on each bracket.
For installation of window guards and stops on metal frames, we
recommend purchasing and substituting with an appropriate
tamper-resistant fastener, made specically for metal applications.
(Minimum size: #10 with a 1-1/2" length)
For either sliding windows or casement windows,
the window guard must cover the entire opening of the window.
Painting and Maintenance
This product is constructed of steel for strength, durability, and security,
throughly cleaned and painted with a baked on powder-coating.
However, due to the narure of steel, exposed, scratched, or scraped
areas will rust. Immediately upon completion of your installation, touch
up all areas that may have been scratched or scraped during
installation, using a rust inhibitive paint. Periodically check for signs of
wear and oxidation and maintain as necessary.
Hinged Horizontal
Window Guard
Possible Fall Hazard
WARNING!
!
• Young children may fall out the window if the window fall prevention device is not installed
correctly.
- Install the device so that a rigid 4 inch diameter sphere does not pass through any space
in the window opening after the window fall prevention device is in place.
• Young children may fall out the window if all installation instructions are not followed:
- Use recommended materials and techniques
- Make sure the fall prevention device is securely attached to the window frame
- Make sure the window frame is in good condition
Installed too highInstalled too low
DO NOT INSTALL window fall prevention device on:
- Emergency escape and rescue windows
- Fire escape windows
- Windows at or below 75 feet above ground level
(unless approved by applicable building and/or re codes)
• Use of this window fall prevention device on escape and
rescue windows may result in death by entrapment
during re or emergency.
Check building and re codes before installing window
fall prevention devices. Contact local building code
department or re department for specic codes.
Page view 0
1

Summary of Contents

Page 1 - Window Guard

Fig. CWindow stop L-bracket installationVertical channel1/2" off sillSecure window stop L-brackets withone-way screws4" maximumclearance bel

Comments to this Manuals

No comments